Heat Pump Doctors logo, Auckland Heat Pump Repairs home page 0800 211 407

Heat pump not heating or cooling

It’s on, the fan’s blowing, but the air’s barely warm. Or it’s summer and it’s pushing room-temperature air at you. We work out which part has stopped doing its job, and Phil’s an electrician by trade, so the electrical causes get properly checked.

ACHOLDREADYV~NO HEATSENSOR · BOARDFAN · OUTDOOROFFNO HEATNO COOLTRIPSLEAKNOISYERRORNO STARTCOMV ΩA

Handy for us to know

  • Heating, cooling or both
  • Whether the outdoor unit runs
  • Any lights or code on the remote
  • The brand and model
Send us the fault
Since 2012
Heat Pump Doctors has worked on heat pumps since 2012
Electrician
Phil’s own trade, so the electrical side is checked properly
Main brands
Mitsubishi Electric, Fujitsu, Panasonic, Daikin, Hitachi, Toshiba
Saturdays
Weekdays 9 till 5, and Saturdays 9 till 4

Check these two first

Make sure the remote is on HEAT, not AUTO, DRY or FAN, with the set temperature a few degrees above the room. After a power cut or a fiddling child, it’s worth a look.

Then give it ten minutes. In heating, a heat pump holds the fan back until the coil has warmed up, and in cold weather it stops now and then to clear frost off the outdoor unit. If it’s still cool after that, something has failed.

What stops the heat

  • A sensor reading the room wrong. The unit thinks it’s already warm and backs off. Room and coil temperature sensors make up a long list in the makers’ own fault codes.
  • The indoor fan motor. A weak or seized fan moves too little air, so the coil overheats in heating or freezes in cooling and the unit protects itself.
  • A control board. The indoor board runs the fan and reads the sensors; the outdoor board drives the compressor. When either fails, the heat goes.
  • The link between the units. The indoor and outdoor units talk over a cable. A loose terminal or a damaged run and the outdoor unit never gets told to start.
  • The outdoor unit itself. Its fan, the compressor drive, or low refrigerant from a slow leak.

Every one of those but the last is electrical, and the outdoor unit’s drive and fan motor are too. That’s why we test the electrical side before anything else.

When it won’t cool

Cooling faults follow the same trail. A sensor that reads the room as cold, a fan that can’t move enough air, or an outdoor unit that never gets the signal to start will all leave you with a fan blowing warm air.

In an upstairs bedroom or a top-floor apartment you’ll notice it first. Tell us whether it cooled properly last summer, and whether the outdoor unit’s fan is turning.

How we find it

We start with what the unit says about itself, any stored fault, then check the supply and the cable between the units, the sensors, the fan motors and the boards. Gas pressure and the outdoor coil come after that.

Once we’ve found it, we tell you what’s failed and what the repair will take before anything goes ahead.

What a customer said

Phil and the team were fantastic helping us with our 5-bedroom house. We had terrible airflow and outdated systems that hadn’t been maintained, which made things tricky, especially for a 1970s home. Despite the challenges, the team handled everything professionally, and we’re extremely happy with the service. Highly recommend!

Kaleb B. Google review · March 2026

Where we fix them

Also Avondale, Blockhouse Bay, Ellerslie, Glen Innes, Greenlane, Grey Lynn, Hillsborough, Kohimarama, Lynfield, Meadowbank, Mission Bay, Mt Albert, Mt Wellington, New Windsor, One Tree Hill, Parnell, Point Chevalier, Point England, Royal Oak, Sandringham, St Heliers, St Johns, Stonefields, Three Kings, Waterview, Westmere, Ōrākei. All suburbs

Not heating questions

Anything else, ring 0800 211 407 or ask in the form.

Why does my heat pump blow cold air when it first starts?

In heating it holds the fan back until the coil warms up, and it pauses now and then to clear frost off the outdoor unit. If it’s still blowing cold after ten minutes, there’s a fault worth finding.

The outdoor unit isn’t running. What does that mean?

The outdoor unit isn’t being told to start, or can’t. That points to the cable between the units, a board or the supply, which are all electrical checks.

It heats one day and not the next. Is that still a fault?

Yes. An on-and-off fault is often a sensor or a loose connection. Note when it happens and any lights or code, and tell us when you send it through.

Tell us how it’s heating

“Not heating” is already picked. Change it to “Not cooling” if that’s you, add the brand and model, and we’ll call you back.

Call 0800 211 407

What helps us most

  • What it’s doing, and when it started
  • The make and model on the unit’s label
  • Any code on the remote or the lights
  • A photo of the label or the indoor unit

Open weekdays from 9 till 5, and on Saturdays from 9 till 4.

If the remote or the lights show a code, put it here.

    Fields are required unless marked optional. Privacy policy