Daikin heat pump repairs in Auckland
A Daikin with its operation lamp blinking has found a fault and stopped. We repair Daikin wall, floor and ducted units across central Auckland, and since Phil’s an electrician by trade, the boards and sensors behind most Daikin faults are where we start.
Worth sending us
- What the unit is doing
- Whether the lamp blinks or stays on
- The model off the front label
- Wall, floor or ducted
- Since 2012
- Heat Pump Doctors has worked on heat pumps since 2012
- Electrician
- Phil’s own trade, so the electrical side is checked properly
- Main brands
- Mitsubishi Electric, Fujitsu, Panasonic, Daikin, Hitachi, Toshiba
- Saturdays
- Weekdays 9 till 5, and Saturdays 9 till 4
The electrical side of a Daikin
Of the 67 Daikin fault codes we work from, 41 point to an electrical part: the indoor and outdoor boards, the fan motors, a long list of temperature sensors, the inverter, and the link between the units. Daikin even has a code for the supply voltage being too low or too high.
One Daikin habit is worth knowing. If the unit stops but the operation lamp stays lit rather than blinking, it’s protecting itself from a voltage problem and should restart by itself in about three minutes. If it keeps doing it, the supply is worth checking, and that’s electrician’s work.
Finding your Daikin model
On the current wall units, Alira X, Cora, the Lite range and Zena, the model name label sits on the lower right of the front edge, near the display. The model starts FTXM on an Alira X, FTXV on a Cora and FTXF on the Lite range.
The display brightness can be turned down or off, so a dark Daikin may still be running. And after the breaker’s been switched back on, it can take several minutes before any air comes out.
Ducted Daikin systems
Daikin’s ducted units report faults on the wall controller. The older rectangular controllers show an error message and ask you to press the menu button, which brings up the code and the unit number.
The newer round Madoka controller, in its default setting, keeps its ring steady on a fault instead of blinking it, so a stopped system can look like it’s idling. If the rooms have gone cold, check the controller’s menu for a message and send it to us.
Other brands we repair
- Mitsubishi ElectricWall, floor and ducted Mr Slim, and how to tell it from Mitsubishi Heavy
- FujitsuNow sold as GENERAL; older units use different lamp patterns
- PanasonicSensors first, and which light means trouble
- HitachiairHome and older units, not heating or not starting
- ToshibaHome units and RAV light commercial high walls
Daikin questions
Anything else, ring 0800 211 407 or ask in the form.
My Daikin stopped but the lamp is still on. What does that mean?
That’s the unit protecting itself from a voltage problem. It restarts by itself in about three minutes. If it keeps happening, send it through and we’ll check the supply.
Where is the model on my Daikin?
On the current wall units it’s on a label at the lower right of the front edge, near the display.
Can you repair a ducted Daikin?
Yes. Send us what the wall controller shows, including any code and unit number, and the model.
Send us your Daikin fault
Daikin is already picked. Add what it’s doing, the model number and where you are, and we’ll call you back.
What helps us most
- What it’s doing, and when it started
- The make and model on the unit’s label
- Any code on the remote or the lights
- A photo of the label or the indoor unit
Open weekdays from 9 till 5, and on Saturdays from 9 till 4.
Got it. Thanks.
We’ll ring you to talk about the fault and sort a time.